PRODUCT
LC300/450I LC300/530I LC300/550I LC350/500I LC400/500I LC400/540I LC450/550I LB-LK7-120 mechanical seal
HTM/HRM/HR325/HMR3C/LB type mechanical seal for Xiangyang 525 LC/LCF wear-resistant and corrosion-resistant pump
Mechanical seals are divided into single end manifold and double end manifold
Single-end face manifold type: There is only one pair of sealing joint faces, which are pre-assembled by the sealing manufacturer before leaving the factory. No customer adjustment is required, just assembling directly. Easy to install and simple to use. The cooling water pressure is controlled between 0.05-0.1MPa
Single end face seal picture
Double-end-face container type: There are 2 pairs of sealing joint surfaces, which are pre-assembled by the sealing manufacturer when leaving the factory. No customer adjustment is required, just assembling directly. Easy to install and simple to use. The cooling water pressure is controlled between 0.05-0.1MPa
Double end face seal picture
The double end face generally refers to the exterior double end face, which is a derivative of the single end face exterior type (the single end face seal water side skeleton oil seal is changed to a set of tandem mechanical seals) to increase the service life
Structural features:
Single end face (double end face) cartridge mechanical seal. Easy to install and simple to use. Balance, arbitrary rotation.
The internal working length is short. The static ring compensation multiple springs are externally not in contact with the medium.
Applicable medium:
Medium containing high impurity content such as gypsum and lime slurry.
Working parameters:
Fixed content: ≤30%
Temperature: ≤280℃
Pressure: ≤2.5MPa
Shaft diameter: ≤200mm
Material parameters:
Body material: 316L or 2205, 2507, 1.4529
Seal ring material: SSiC or SiC
Rubber material: fluorine rubber or perfluoroether rubber
main application:
This type of mechanical seal is mainly used for flue gas desulfurization of coal-fired power generation, and is suitable for absorption tower slurry circulation pump, gypsum slurry pump, limestone slurry pump, and gypsum discharge pump.
Common pump numbers are as follows:
LCF40/250I LCF40/350I LCF40/400I LCF40/450I LCF50/350N2 LCF50/400I LCF50/460I LCF65/310I LCF65/315I LCF65/350I LCF65/400I LCF80/400I LCF80/450I LCF100/300 LCF100/320I LCF100/350I LCF100/320I LCF100/350I 420I LCF125/405I LCF150/300I LCF150/350I LCF200/300I LCF100/500T LCF150/400I LCF200/410I LCF250/430I LCF250/430I LC300/500I LC300/530I LC300/400I LC300/635I
LC300/630I LC350/500I LC350/560I LC400/500I LC400/540I LC450/635I LC500/630I LC550/700I LC550/710I LC550/750I LC600/825I LC700/900I LC700/898I LC800/1000I LC900/1150I
LC500/630II LC550/700II LC550/710II LC550/750II LC600/825II LC700/900II LC700/898II LC800/1000II LC900/1150II
Seal model:
HTM-30S251Z HTM-30S351X HTM-30S220Z HTM-30S220Q
HTM-30D251ZZ HTM-30D351X
HTM-40S251Z HTM-40S351X HTM-40S220Z HTM-40S220Q
HTM-40D251ZZ HTM-40D351XX
HTM-55S251Z HTM-55S351X HTM-55S220Z HTM-55S220Q
HTM-55D251ZZ HTM-55D351XX
HTM-60S251Z HTM-60S351X HTM-60S220Z HTM-60S220Q
HTM-60D251ZZ HTM-60D351XX
HTM-80S251Z HTM-80S351X HTM-80S220Z HTM-80S220Q
HTM-80D251ZZ HTM-80D351XX
LB-LK7-120S LB-LK7-120D LB-LK6-115S LB-LK6-115D
HTM-30S HTM-40S HTM-55S HTM-60S HTM-80S
HTM-30D HTM-40D HTM-55D HTM-60D HTM-80D
HR3-125 HR3-142 HR3-158 HR3-175 HR3-198
HR325/230 HR325/210 HR325/190 HR325/170
HRM-125D3 HRM-142D3 HRM-158D3 HRM-175D3 HRM-198D3
HRM-125S3 HRM-142S3 HRM-158S3 HRM-175S3 HRM-198S3
HMR3C-125 HMR3C-142 HMR3C-158 HMR3C-175 HMR3C-198
Installation and use requirements:
1. The radial runout of the shaft of the equipment should not be greater than 0.04 mm, and the axial runout is not allowed to be greater than 0.1 mm;
2. The sealing cavity of the equipment should be kept clean during installation, the sealing parts should be cleaned, and the sealing end face should be intact to prevent impurities and dust from being brought into the sealing part;
3. It is strictly forbidden to knock or knock during the installation process, so as not to damage the mechanical seal due to friction and seal failure;
4. During installation, the surface in contact with the seal should be coated with a layer of clean mechanical oil for smooth installation;
5. When installing the static ring gland, the tightening screws must be evenly stressed to ensure that the end face of the static ring is perpendicular to the axis line;
6. Push the moving ring by hand after installation, which can make the moving ring move flexibly on the shaft and have certain flexibility;
7. Rotate the shaft by hand after installation, and the shaft should not feel light or heavy;
8. The equipment must be filled with medium before operation to prevent dry friction and seal failure;
Service hotline:0813-3202978