PRODUCT
HRL-65 HRL-75 HRL-90 HRL-110 mechanical seal for SC side mixing
Xiangyang 525 SC type HRL cartridge type mechanical seal for side mixing
Material parameters:
Body material: 316L or 2205, 2507, 1.4529
Seal ring material: SSiC or SiC
Rubber material: fluorine rubber or perfluoroether rubber
Structural features of mechanical seal:
Single end face, cartridge type, multiple springs, bearing type
Static type, spring external type, flange internal type
Applicable medium:
Medium containing high impurity content such as gypsum and lime slurry.
Working parameters:
Fixed content: ≤30%
Temperature: ≤120℃
Pressure: ≤2.5MPa
Shaft diameter: ≤120mm
main application:
The seal is mainly used for the side agitator of the absorption tower in the coal-fired power generation flue gas desulfurization device, and can also be used for the reactor in the chemical industry, papermaking and other industries.
Common agitator models are as follows:
SC65-800-11/243 SC65-800-11/250 SC65-800-11/327 SC65-800-15/207
SC75-800-15/243 SC75-800-15/250 SC75-800-15/327 SC75-1000-7.5/207
SC90-1000-15/243 SC90-1000-15/250 SC90-1000-15/327 SC90-1000-18.5/207
SC110-1600-37/122 SC110-1600-37/115 SC110-1600-45/122 SC110-1600-45/110
Mechanical seal model:
HRL(WS)-60 HRL(WS)-65 HRL(WS)-70 HRL(WS)-75
HRL(WS)-80 HRL(WS)-85 HRL(WS)-90 HRL(WS)-95
HRL(WS)-100 HRL(WS)-105 HRL(WS)-110 HRL(WS)-115
HRL(WS)-120
Installation and use requirements:
1. The radial runout of the shaft of the equipment should not be greater than 0.04 mm, and the axial runout is not allowed to be greater than 0.1 mm;
2. The sealing cavity of the equipment should be kept clean during installation, the sealing parts should be cleaned, and the sealing end face should be intact to prevent impurities and dust from being brought into the sealing part;
3. It is strictly forbidden to knock or knock during the installation process, so as not to damage the mechanical seal due to friction and seal failure;
4. During installation, the surface in contact with the seal should be coated with a layer of clean mechanical oil for smooth installation;
5. When installing the static ring gland, the tightening screws must be evenly stressed to ensure that the end face of the static ring is perpendicular to the axis line;
6. Push the moving ring by hand after installation, which can make the moving ring move flexibly on the shaft and have certain flexibility;
7. Rotate the shaft by hand after installation, and the shaft should not feel light or heavy;
8. The equipment must be filled with medium before operation to prevent dry friction and seal failure;
Service hotline:0813-3202978
Working days: Monday to Saturday
Time:8:30-18:00
Tell:
0813-3202978
Email:
Consulting:
13890019297