NM011BY02S12B NM021BY02S12B NM031BY01S06B NM038BY01S06B NM045BY02S12B NM053BY01P06B NM063BY01L06B NM076BY01P06B NM090BY01L06B mechanical seal
Structural features:
1. Single end face, wave spring, compact structure. When in use, regardless of the spring rotation direction.
2. The auxiliary sealing ring can be nitrile rubber, fluorine rubber, ethylene propylene rubber according to different conditions.
3. It complies with ISO3069, DIN24960 and GB6556 standards and has strong versatility.
Applicable medium:
Oil, water, acid, alkali, salt, etc.
Working parameters:
Fixed content: ≤10%
Temperature: ≤180℃
Pressure: ≤1.0MPa
Shaft diameter: ≤100mm
Material parameters:
Body material: 304, 316L or 2205, 2507, 1.4529
Seal ring material: graphite, silicon carbide, tungsten carbide
main application:
This type of mechanical seal is mainly used for various hot water pumps, starting oil pumps, and ignition oil pumps.
Common models:
NM011BY02S12B NM021BY02S12B
NM031BY02S12B NM045BF02S12B
NM063BY01P05B NM076BY01P05B
Note: Because the pump has many uses, the sealing material (friction pair) is also different to ensure the reliability of the seal.
The manufacturer recommends as follows:
1. Clean oil (working condition without particulate matter)-use of moving ring friction pair (alloy), static ring friction pair (graphite)
2. Strong corrosion (conditions containing particulate matter)-selection of moving ring friction pair (silicon carbide), static ring friction pair selection (silicon carbide)
3. Working conditions that contain particles and have large vibrations-use of moving ring friction pair (alloy), static ring friction pair (alloy)
4. It can also be customized according to customer requirements. If there is no requirement, the default is (clear water)
Installation and use requirements:
1. The radial runout of the shaft of the equipment should not be greater than 0.04 mm, and the axial runout is not allowed to be greater than 0.1 mm;
2. The sealing cavity of the equipment should be kept clean during installation, the sealing parts should be cleaned, and the sealing end face should be intact to prevent impurities and dust from being brought into the sealing part;
3. It is strictly forbidden to knock or knock during the installation process, so as not to damage the mechanical seal due to friction and seal failure;
4. During installation, a layer of clean mechanical oil should be applied to the surface in contact with the seal for smooth installation;
5. When installing the static ring gland, the tightening screws must be evenly stressed to ensure that the end face of the static ring is perpendicular to the axis line;
6. Push the moving ring by hand after installation, which can make the moving ring move flexibly on the shaft and have certain flexibility;
7. Rotate the shaft by hand after installation, and the shaft should not feel light or heavy;
8. The equipment must be filled with medium before operation to prevent dry friction and seal failure;
Service hotline:0813-3202978