PRODUCT
SE750 SE1500 SE1100 SE1850 SE2200 SE3000 SE3700 SE4500 mechanical seal for SARDIK side mixing
Material parameters:
Body material: 316L or 2205, 2507, 1.4529
Seal ring material: SSiC or SiC
Rubber material: fluorine rubber or perfluoroether rubber
Structural features of mechanical seal:
Single end face, cartridge type, multiple springs, without bearing
Static type, spring external type, flange internal type
Applicable medium:
Medium containing high impurity content such as gypsum and lime slurry.
Working parameters:
Fixed content: ≤30%
Temperature: ≤120℃
Pressure: ≤2.5MPa
Shaft diameter: ≤120mm
main application:
The seal is mainly used for the side agitator of the absorption tower in the coal-fired power generation flue gas desulfurization device, and can also be used for the reactor in the chemical industry, papermaking and other industries.
Common agitator models are as follows:
SE550-600 SE750-600 SE1100-600
SE1500-600 SE1850-600 SE2200-600
SE3000-600 SE3700-600 SE4000-600
SE3700-600 SE4500-600 SE5500-600
SDK550 SDK750 SDK1100 SDK1500
SDK1850 SDK2200 SDK3000 SDK3700
SDK3000 SDK3700 SDK4500 SDK5500
Mechanical seal model:
SDK-14A-62-15 SDK-14A-62-18.5
SDK-12-75-22 SDK-12-75-30
Installation and use requirements:
1. The radial runout of the shaft of the equipment should not be greater than 0.04 mm, and the axial runout is not allowed to be greater than 0.1 mm;
2. The sealing cavity of the equipment should be kept clean during installation, the sealing parts should be cleaned, and the sealing end face should be intact to prevent impurities and dust from being brought into the sealing part;
3. It is strictly forbidden to knock or knock during the installation process, so as not to damage the mechanical seal due to friction and seal failure;
4. During installation, the surface in contact with the seal should be coated with a layer of clean mechanical oil for smooth installation;
5. When installing the static ring gland, the tightening screws must be evenly stressed to ensure that the end face of the static ring is perpendicular to the axis line;
6. Push the moving ring by hand after installation, which can make the moving ring move flexibly on the shaft and have certain flexibility;
7. Rotate the shaft by hand after installation, and the shaft should not feel light or heavy;
8. The equipment must be filled with medium before operation to prevent dry friction and seal failure;