PRODUCT
CFJ2-4 / 230 CFJ2-5.5 / 330 CFJ3-5.5 / 290 CFJ3-7.5 / 290 CFJ4-18.5 / 290 CFJ4-22 / 230 Machine Sealing
Material parameters:
Body material: 316L or 2205, 2507, 1.4529
Seal ring material: SSiC or SiC
Rubber material: fluorine rubber or perfluoroether rubber
Structural features of mechanical seal:
Single end face, cartridge type, multiple springs, without bearing
Static type, spring external type, flange internal type
Applicable medium:
Medium containing high impurity content such as gypsum and lime slurry.
Working parameters:
Fixed content: ≤30%
Temperature: ≤120℃
Pressure: ≤2.5MPa
Shaft diameter: ≤120mm
main application:
The seal is mainly used for the side agitator of the absorption tower in the coal-fired power generation flue gas desulfurization device, and can also be used for the reactor in the chemical industry, papermaking and other industries.
Common agitator models are as follows:
CFJ2-2.2/350 CFJ2-2.2/280 CFJ2-2.2/230
CFJ2-2.2/190 CFJ2-3/350 CFJ2-3/280
CFJ2-3/230 CFJ2-3/190 CFJ2-4/350
CFJ2-4/280 CFJ2-4/230 CFJ2-4/190
CFJ3-5.5/350 CFJ3-5.5/290 CFJ3-5.5/230
CFJ3-5.5/190 CFJ3-7.5/350 CFJ3-7.5/290
CFJ3-7.5/230 CFJ3-7.5/190 CFJ3-11/350
CFJ3-11/290 CFJ3-11/230 CFJ3-11/190
CFJ4-15/350 CFJ4-15/280 CFJ4-15/230
CFJ4-15/190 CFJ4-18.5/350 CFJ4-18.5/280
CFJ4-18.5/230 CFJ4-18.5/190 CFJ4-22/350
CFJ4-22/280 CFJ4-22/230 CFJ4-22/190
CFJ5-30/350 CFJ5-30/250 CFJ5-30/230
CFJ5-30/190 CFJ5-37/350 CFJ5-37/250
CFJ5-37/230 CFJ5-37/190 CFJ5-45/350
CFJ5-45/250 CFJ5-45/230 CFJ5-45/190
Mechanical seal model:
261-45S15 261-50S15 261-55S15 261-60S15
261-65S15 261-70S15 261-75S15 261-80S15
261-85S15 261-90S15 261-95S15 261-100S15
Installation and use requirements:
1. The radial runout of the shaft of the equipment should not be greater than 0.04 mm, and the axial runout is not allowed to be greater than 0.1 mm;
2. The sealing cavity of the equipment should be kept clean during installation, the sealing parts should be cleaned, and the sealing end face should be intact to prevent impurities and dust from being brought into the sealing part;
3. It is strictly forbidden to knock or knock during the installation process, so as not to damage the mechanical seal due to friction and seal failure;
4. During installation, the surface in contact with the seal should be coated with a layer of clean mechanical oil for smooth installation;
5. When installing the static ring gland, the tightening screws must be evenly stressed to ensure that the end face of the static ring is perpendicular to the axis line;
6. Push the moving ring by hand after installation, which can make the moving ring move flexibly on the shaft and have certain flexibility;
7. Rotate the shaft by hand after installation, and the shaft should not feel light or heavy;
8. The equipment must be filled with medium before operation to prevent dry friction and seal failure;
Service hotline:0813-3202978