- All
- Product Management
- News and Information
- Introduction content
- Business outlets
- Frequently Asked Questions
- Corporate Video
- Corporate Portfolio
PRODUCT
SLJY32-250, SLJY32-330, SLJY40-250, SLJY40-315, SLJY40-350, SLJY40-400, SLJY50-315, SLJY50-400, SLJY50-500, SLJY65-200, SLJY65-250, SLJY65-315, SLJY80-250, SLJY80-315, SLJY80-400, SLJY100-250, SLJY100-315, SLJY100-350, SLJY100-400, SLJY150-315, SLJY150-400, SLJY200-315 Mechanical Seals
Product Name: Mechanical Seal Application Scope: Chemical pumps, slurry pumps, desulfurization pumps, and circulating pumps Applicable Industries: Steelmaking, paper production, chemical processing, power generation, cement manufacturing, and more Suitable Applications: Slurry pumps, gypsum pumps, and limestone pumps
Keywords:
SLJY32-250, SLJY32-330, SLJY40-250, SLJY40-315, SLJY40-350, SLJY40-400, SLJY50-315, SLJY50-400, SLJY50-500, SLJY65-200, SLJY65-250, SLJY65-315, SLJY80-250, SLJY80-315, SLJY80-400, SLJY100-250, SLJY100-315, SLJY100-350, SLJY100-400, SLJY150-315, SLJY150-400, SLJY200-315 Mechanical Seals
- Product Description
- parameter
-
- Commodity name: SLJY32-250, SLJY32-330, SLJY40-250, SLJY40-315, SLJY40-350, SLJY40-400, SLJY50-315, SLJY50-400, SLJY50-500, SLJY65-200, SLJY65-250, SLJY65-315, SLJY80-250, SLJY80-315, SLJY80-400, SLJY100-250, SLJY100-315, SLJY100-350, SLJY100-400, SLJY150-315, SLJY150-400, SLJY200-315 Mechanical Seals
- Commodity ID: CMDT-00095
Product Name: Mechanical Seal Application Scope: Chemical pumps, slurry pumps, desulfurization pumps, and circulating pumps Applicable Industries: Steelmaking, paper production, chemical processing, power generation, cement manufacturing, and more Suitable Applications: Slurry pumps, gypsum pumps, and limestone pumps

Structural features:
Double-end face modular mechanical seal. Easy to install and simple to use. Balanced design, reversible rotation.
Internal working length is short. The stationary ring features multi-spring external compensation that does not come into contact with the medium.
Applicable medium:
A medium with a high content of impurities such as gypsum and lime slurry.
Work parameters:
Fixed substance content: ≤30%
Warm Temperature: ≤280°C
Press Force: ≤2.5 MPa
Axis Diameter: ≤220mm
Material parameters:
Main material: 316L or 2205, 2507, 1.4529
Sealing ring material: SSiC or SiC
Rubber materials: Fluororubber or perfluoroether rubberMain applications:
This type of mechanical seal is primarily used in flue gas desulfurization systems for coal-fired power plants, and is suitable for absorption tower slurry circulation pumps, gypsum slurry pumps, limestone slurry pumps, and gypsum discharge pumps.
Common pump numbers are as follows:
SLJY40-200 SLJY40- 250 SLJY40-250
SLJY40-315 SLJY40-350 SLJY40-400
SLJY 5 0-2 00 SLJY 5 0- 250 SLJY50-250
SLJY50-315 SLJY50-350 SLJY50-400
SLJY 65 -2 00 SLJY 65-250 SLJY65-250
SLJY65-315 SLJY65-350 SLJY65-400
SLJY 8 0-2 00 SLJY 8 0- 250 SLJY80-250
SLJY80-315 SLJY80-350 SLJY80-400
SLJY 10 0-2 00 SLJY 10 0- 250 SLJY100-250
SLJY100-315 SLJY100-350 SLJY100-400
SLJY100-500 SLJY125-250 SLJY 125 -2 00
SLJY 125-250 SLJY125-315 SLJY125-350
SLJY125-400 SLJY125-500 SLJY 15 0-2 00
SLJY 15 0- 250 SLJY150-250 SLJY150-315
SLJY150-350 SLJY150-400 SLJY150-500
SLJY150-400 SLJY 20 0-2 00 SLJY 20 0- 250
SLJY 20 0-250 SLJY 20 0-315 SLJY 20 0-350
SLJY 20 0-400 SLJY 20 0-500 SLJY 20 0-400
SLJY 25 0-250 SLJY 25 0-315 SLJY 25 0-350
SLJY 25 0-400 SLJY 25 0-500 SLJY 25 0-400
Installation Use Requirements :
1. The radial runout of the equipment shaft should not exceed 0.04 mm, with axial runout not exceeding 0.1 mm;
2. The sealing cavity of the equipment should be kept clean during installation, and sealing components must be thoroughly cleaned. Ensure that the sealing faces remain intact to prevent contaminants and dust from entering the sealing area.
3. During installation, avoid any impact or hammering to prevent damaging the mechanical seal through friction, which could lead to sealing failure.
4. During installation, apply a layer of clean machine oil to the surfaces that will come into contact with the seal, ensuring smooth installation.
5. When installing the stationary ring gland, tighten the screws evenly to ensure the stationary ring face is perpendicular to the shaft centerline.
6. After installation, gently push the moving ring by hand to ensure it moves freely along the shaft while maintaining some elasticity.
7. After installation, manually rotate the shaft—there should be no sensation of unevenness or heaviness.
8. Before starting operation, the equipment must be fully charged with the medium to prevent dry friction, which could lead to seal failure.Key words:- 脱硫泵机械密封石膏排出泵机械密封浆液泵机械密封滤液水泵机械密封
-
-
Operating parameters:
- Specifications: 45mm to 220mm
- Pressure: 0–2.5 MPa
- Temperature: -20 to 280
- Linear velocity: ≤15 m/min
- Suitable medium: A medium with a high content of impurities such as gypsum and lime slurry.
-
Product features:
- Sealing surface: Graphite, cemented carbide, silicon carbide
- Auxiliary seal: Nitrile, ethylene propylene, fluoroelastomer, silicone rubber, and more
- Metal components: 304, 316L, 2205, 2507, 1.4529
- Structural features: Modular mechanical seals offer convenient installation and simple operation; they provide balanced performance and can rotate in either direction.
-