PRODUCT
DFW100-160(I) DFW125-125(I) DFG50-160/2/3 DFG100-200/2/22 mechanical seal
Structural features:
1. Single end face, rubber bellows compensation, strong anti-blocking ability. When in use, regardless of the spring rotation direction.
2. The auxiliary sealing ring is nitrile rubber, fluorine rubber, ethylene propylene rubber, silicon rubber.
3. It complies with ISO3069, DIN24960 and GB6556 standards and has strong versatility.
Applicable medium:
Oil, water, acid, alkali, salt and other clean water and waste water, sewage, and dirty oil containing particles.
Working parameters:
Fixed content: ≤10%
Temperature: ≤180℃
Pressure: ≤1.5MPa
Shaft diameter: ≤100mm
Material parameters:
Body material: 304, 316L or 2205, 2507, 1.4529
Seal ring material: graphite, silicon carbide, tungsten carbide
main application:
This type of mechanical seal is mainly used for various water pumps, chemical pumps, sewage pumps, waste water pumps, and slop oil pumps.
Common models:
DFW40-125(I) DFW40-125A DFW40-160(I)
DFW40-160A DFW40-160B DFW40-200(I)
DFW40-200A DFW40-200B DFW40-250(I)
DFW40-250A DFW40-250B DFW50-100(I)
DFW50-100(I)A DFW50-125(I) DFW50-125(I)A
DFW50-160(I) DFW50-160A DFW50-160B
DFW50-200(I) DFW50-200A DFW50-200B
DFW50-250(I) DFW50-250A DFW50-250B
DFW50-250C DFW65-100(I) DFW65-100A
DFW65-125(I) DFW65-125A DFW65-160(I)
DFW65-160A DFW65-160B DFW65-200(I)
DFW65-200A DFW65-200B DFW65-250(I)
DFW65-250A DFW65-250B DFW65-250C
DFW65-315(I) DFW65-315A DFW65-315B
DFW65-315C DFW80-100(I) DFW80-100A
DFW80-125(I) DFW80-125A DFW80-160(I)
DFW80-160A DFW80-160B DFW80-200(I)
DFW80-200A DFW80-200B DFW80-250(I)
DFW80-250A DFW80-250B DFW80-315(I)
DFW80-315A DFW80-315B DFW80-315C
DFW100-100(I) DFW100-100A DFW100-125(I)
DFW100-125A DFW100-160(I) DFW100-160A
DFW100-160B DFW100-200(I) DFW100-200A
DFW100-200B DFW100-250(I) DFW100-250A
DFW100-250B DFW100-315(I) DFW100-315A
DFW100-315B DFW100-315C DFW125-125(I)
DFW125-125A DFW125-160(I) DFW125-160A
DFW125-160B DFW125-200(I) DFW125-200A
DFW125-200B DFW125-250(I) DFW125-250A
DFW125-250B DFW125-315(I) DFW125-315A
DFW125-315B DFW125-315C DFW150-125(I)
DFW150-125(I)A DFW150-160(I) DFW150-160(I)A
DFW150-160(I)B DFW150-200(I) DFW150-250(I)
DFW150-315(I) DFW150-200(I) DFW150-400
DFW150-500 DFW200-200(I) DFW200-250(I)
DFW200-315(I) DFW200-400(I)A DFW200-400(I)B
DFW200-500(I)A DFW250-250 DFW250-315
DFW250-315A DFW250-315B DFW250-400(I)
DFW300-250 DFW300-315 DFW300-400A
DFG25-100/2/0.37 DFG50-160/2/3
DFG80-315/2/37 DFG150-160/2/22
DFG65-315/4/5.5 DFG25-125/2/0.75
DFG50-200/2/5.5 DFG100-125/2/11
DFG150-250/2/55 DFG80-200/4/3
DFG25-160/2/1.1 DFG50-250/2/11
DFG100-160/2/15 DFG40-200/4/0.75
DFG80-250/4/5.5 DFG32-100/2/0.55
DFG65-100/2/1.5 DFG100-200/2/22
DFG40-250/4/1.5 DFG80-400/4/15
DFG32-125/2/0.75 DFG65-160/2/4
DFG100-250/2/37 DFG40-315/4/3
DFG80-500/4/30 DFG32-200/2/3
DFG65-250/2/15 DFG100-315/2/75
DFG50-200/4/1.1 DFG100-315/4/15
DFG40-100/2/0.55 DFG65-315/2/30
DFG125-160/2/22 DFG50-315/4/4
DFG100-500/4/45 DFG40-160/2/2.2
DFG80-160/2/7.5 DFG125-200/2/37
DFG50-400/4/7.5 DFG125-315/4/22
DFG40-200/2/4 DFG80-200/2/15
DFG125-250/2/55 DFG65-200/4/1.5
DFG125-500/4/75 DFG50-100/2/1.1
DFG80-250/2/22 DFG150-125/2/15
DFG65-250/4/3 DFG80-250/2/22
Note: Because the pump has many uses, the sealing material (friction pair) is also different, in order to ensure the reliability of the seal
The manufacturer recommends as follows:
1. Clean water (working condition without particulate matter)-select the friction pair of moving ring (alloy), select the friction pair of static ring (graphite)
2. Strong corrosion (conditions containing particulate matter)-selection of moving ring friction pair (silicon carbide), static ring friction pair selection (silicon carbide)
3. Working conditions that contain particles and have large vibrations-use of moving ring friction pair (alloy), static ring friction pair (alloy)
4. It can also be customized according to customer requirements. If there is no requirement, the default is (clear water)
Installation and use requirements:
1. The radial runout of the shaft of the equipment should not be greater than 0.04 mm, and the axial runout is not allowed to be greater than 0.1 mm;
2. The sealing cavity of the equipment should be kept clean during installation, the sealing parts should be cleaned, and the sealing end face should be intact to prevent impurities and dust from being brought into the sealing part;
3. It is strictly forbidden to knock or knock during the installation process, so as not to damage the mechanical seal due to friction and seal failure;
4. During installation, the surface in contact with the seal should be coated with a layer of clean mechanical oil for smooth installation;
5. When installing the static ring gland, the tightening screws must be evenly stressed to ensure that the end face of the static ring is perpendicular to the axis line;
6. Push the moving ring by hand after installation, which can make the moving ring move flexibly on the shaft and have certain flexibility;
7. Rotate the shaft by hand after installation, and the shaft should not feel light or heavy;
8. The equipment must be filled with medium before operation to prevent dry friction and seal failure;


Service hotline:0813-3202978
Working days: Monday to Saturday
Time:8:30-18:00
Tell:
0813-3202978
Email:
Consulting:
13890019297
Zigong Chuanmi Mechanical seal Co., LTD 蜀ICP备12011709号-1