PRODUCT
JKCF40/250 JKCF40/350 JKCF50/350 JKCF65/310 JKCF80/450 JKCF100/300 JKCF100/350 Mechanical seal
Structural features:
Single end face (double end face) cartridge mechanical seal. Easy to install and simple to use. Balance, arbitrary rotation.
The internal working length is short. The static ring compensation multiple springs are externally not in contact with the medium.
Applicable medium:
Medium containing high impurity content such as gypsum and lime slurry.
Working parameters:
Fixed content: ≤30%
Temperature: ≤280℃
Pressure: ≤2.5MPa
Shaft diameter: ≤200mm
Material parameters:
Body material: 316L or 2205, 2507, 1.4529
Seal ring material: SSiC or SiC
Rubber material: fluorine rubber or perfluoroether rubber
main application:
This type of mechanical seal is mainly used for flue gas desulfurization of coal-fired power generation, and is suitable for absorption tower slurry circulation pump, gypsum slurry pump, limestone slurry pump, and gypsum discharge pump.
Common pump numbers are as follows:
JKCF25/250 JKCF25/350 JKCF32/200
JKCF32/250 JKCF32/250 JKCF32/350
JKCF50/210 JKCF80/210 JKCF32/200
JKCF40/250 JKCF40/250 JKCF40/350
JKCF40/400 JKCF40/450 JKCF50/350N1
JKCF50/350N2 JKCF50/400 JKCF50/460
JKCF65/310 JKCF65/315 JKCF65/400
JKCF65/350 JKCF80/400 JKCF80/450
JKCF100/300 JKCF100/320 JKCF100/350
JKCF100/420 JKCF125/300 JKCF125/350
JKCF125/405 JKCF250/300 JKCF150/310
JKCF150/350A JKCF150/300 JKCF150/350
JKCF200/300 JKCF100/500 JKCF150/400
JKCF200/410 JKCF250/430 JKCF250/350
JKC300/500 JKC300/530 JKC300/450
JKC300/635 JKC300/550 JKC350/500
JKC350/450 JKC350/500 JKC350/560
JKC400/500 JKC350/680 JKC400/540
JKC400/540 JKC400/560 JKC450/550
JKC450/750 JKC450/635 JKC500/630
JKC550/700 JKC550/710 JKC550/750
JKC600/800 JKC600/825 JKC600/800
JKC700/898 JKC700/900 JKC800/1000
JKC900/1150 JKC900/1150 JKC1000/1300
JKC1000/1200 JKC1000/1250 JKC1000/1300
Installation and use requirements:
1. The radial runout of the shaft of the equipment should not be greater than 0.04 mm, and the axial runout should not be greater than 0.1 mm;
2. The sealing cavity of the equipment should be kept clean during installation, the sealing parts should be cleaned, and the sealing end face should be intact to prevent impurities and dust from being brought into the sealing part;
3. It is strictly forbidden to knock or knock during the installation process, so as not to damage the mechanical seal due to friction and seal failure;
4. During installation, the surface in contact with the seal should be coated with a layer of clean mechanical oil for smooth installation;
5. When installing the static ring gland, the tightening screws must be evenly stressed to ensure that the end face of the static ring is perpendicular to the axis line;
6. After installation, push the moving ring by hand, which can make the moving ring move flexibly on the shaft and have certain flexibility;
7. Rotate the shaft by hand after installation, and the shaft should not feel light or heavy;
8. The equipment must be filled with medium before operation to prevent dry friction and seal failure;